Parameters - Technical functions and diagnostics
Parameter no. Description
Operating data
Display text Unit Range
600 Operating hours (OPERATING HOURS) Hours 0 - 130,000.0
601 Hours run (RUNNING HOURS) Hours 0 - 130,000.0
602 kWh counter (KWH COUNTER) kWh 0 - 9999
603 No. of cut-ins (POWER UP's) Nos. 0 - 9999
604 No. of overtemps (OVER TEMP's) Nos. 0 - 9999
605 No. of overvoltages (OVER VOLT'S) Nos. 0 - 9999
Function:
These parameters can be read out via the serial com-
munication port and via the display in the parameters.
Description of choice:
Operating hours , parameter 600:
Indicates the number of hours in which the adjustable
frequency drive has been in operation.
The value is updated in the adjustable frequency drive
every hour and saved when the unit is turned off.
Hours run, parameter 601:
Indicates the number of hours in which the adjustable
frequency drive has been in operation since reset in
parameter 619.
The value is updated in the adjustable frequency drive
every hour and saved when the unit is turned off.
kWh counter , parameter 602:
States the kW consumption of the motor as a mean
value over one hour, since the reset in parameter 618.
No. of cut-ins, parameter 603:
States the number of power-ups of the supply voltage
to the adjustable frequency drive.
No. of overtemps, parameter 604:
States the number of temperature faults there has
been on the adjustable frequency drive.
No. of overvoltages, parameter 605:
States the number of overvoltages there has been on
the adjustable frequency drive.
Parameter no. Description
Data log
Display text Unit Range
606 Digital inputs (LOG: DIGITAL INP) Decimal 0 - 255
607 Control word (LOG: CONTROL WORD Decimal 0 - 65535
608 Status word (LOG: BUS STAT WD) Decimal 0 - 65535
609 Reference (LOG: REFERENCE) % 0 - 100
610 Feedback (LOG: FEEDBACK) Par. 416 999,999.99 -
999,999.99
611 Output frequency (LOG: MOTOR FREQ.) Hz. 0.0 - 999.9
612 Output voltage (LOG: MOTOR VOLT) Volt 50 - 1000
613 Output current (LOG: MOTOR CURR.) Amp 0.0 - 999.9
614 DC link voltage (LOG: DC LINK VOLT) Volt 0.0 - 999.9
Function:
Via this parameter it is possible to see up to 20 data-
logs, where [0] is the latest log and [19] the oldest.
Each data-log is made every 160 ms as long as a start
signal has been given. If a stop signal is given, the lat-
est 20 data-logs will be saved and the values will be
available on the display. This is useful, e.g. when car-
rying out service after a trip.
This parameter can be read out via the serial commu-
nication port or via the display.
Description of choice:
The data-log number is stated in square brackets: [1].
Data-logs are frozen if there is a trip and released
when the adjustable frequency drive is subsequently
reset.
Data-logging is active while the motor is running.
VLT
®
5000 Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark. 149
Programming

Table of Contents

Other manuals for Danfoss VLT 5003

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5003 and is the answer not in the manual?

Danfoss VLT 5003 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5003
CategoryDC Drives
LanguageEnglish

Related product manuals