VLT
®
8000 AQUA
■ Technical data, mains supply 3 x 200 - 240 V
According to international requirements VLT type 8006 8008 8011
Output current
4)
I
VLT,N
[A] 16.7 24.2 30.8
I
VLT, MAX
(60 s) [A] 18.4 26.6 33.9
Output power (240 V) S
VLT,N
[kVA] 6.9 10.1 12.8
Typical shaft output P
VLT,N
[kW] 4.0 5.5 7.5
Typical shaft output P
VLT,N
[HP] 5 7.5 10
Max. cable cross-section to
motor
and DC-bus
[mm
2
]/[AWG]
10/8 16/6 16/6
Max. input current (200 V) (RMS)I
L,N
[A] 16.0 23.0 30.0
Max. cable
cross-section power
[mm
2
]/[AWG]
2)
4/10 16/6 16/6
Max. pre-fuses [-]/UL
1)
[A] 35/30 50 60
Efficiency
3)
0.95 0.95 0.95
Weight IP 20 [kg/lbs] 23/51 23/51 23/51
Weight IP 54 [kg/lbs] 35/77 35/77 38/84
Power loss at
max. load. [W]
Total 194 426 545
Enclosure VLT type IP 20/ NEMA 1, IP 54/NEMA 12
1. Fortypeoffuse,seesectionFuses.
2. American Wire Gauge.
3. Measured using 30 m/100 ft screened motor cables at rated load and rated frequency.
4. Current ratings fulfill UL requirements for 208-240 V.
MG.83.A2.02 - VLT is a registered Danfoss trademark