VLT
®
8000 AQUA
Technical data, mains supply 3 x 200 - 240 V
According to international requirements VLT type 8006 8008 8011
Output current
4)
I
VLT,N
[A] 16.7 24.2 30.8
I
VLT, MAX
(60 s) [A] 18.4 26.6 33.9
Output power (240 V) S
VLT,N
[kVA] 6.9 10.1 12.8
Typical shaft output P
VLT,N
[kW] 4.0 5.5 7.5
Typical shaft output P
VLT,N
[HP] 5 7.5 10
Max. cable cross-section to
motor
and DC-bus
[mm
2
]/[AWG]
10/8 16/6 16/6
Max. input current (200 V) (RMS)I
L,N
[A] 16.0 23.0 30.0
Max. cable
cross-section power
[mm
2
]/[AWG]
2)
4/10 16/6 16/6
Max. pre-fuses [-]/UL
1)
[A] 35/30 50 60
Efficiency
3)
0.95 0.95 0.95
Weight IP 20 [kg/lbs] 23/51 23/51 23/51
Weight IP 54 [kg/lbs] 35/77 35/77 38/84
Power loss at
max. load. [W]
Total 194 426 545
Enclosure VLT type IP 20/ NEMA 1, IP 54/NEMA 12
1. Fortypeoffuse,seesectionFuses.
2. American Wire Gauge.
3. Measured using 30 m/100 ft screened motor cables at rated load and rated frequency.
4. Current ratings fulfill UL requirements for 208-240 V.
MG.83.A2.02 - VLT is a registered Danfoss trademark
36

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 8000 AQUA series and is the answer not in the manual?

Danfoss VLT 8000 AQUA series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 8000 AQUA series
CategoryDC Drives
LanguageEnglish

Related product manuals