EasyManuals Logo
Home>Danfoss>DC Drives>VLT AHF 005

Danfoss VLT AHF 005 Service Guide

Danfoss VLT AHF 005
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #269 background imageLoading...
Page #269 background image
13.2.5 Fan Power Card
To remove or reinstall the fan power card, use the following steps. Refer to Illustration 13.4.
Disassembly
1. Remove the control card mounting plate. Refer to
chapter 13.2.2 Control Card and Control Card
Mounting Plate.
2. Unplug the cables from the following fan power
card connectors:
2a MK600
2b MK602
2c MK802
2d MK803
2e MK1200
3. Release the cables from the cable retaining clips.
4. Remove 6 screws (T20).
5. Remove the fan power card from the 4 plastic
standos, pinching the stando tips to compress
them.
6. Remove the fan power card from the drive.
NOTICE
UNIQUE TORQUE VALUES
Tighten screws (T20) to the non-standard torque value
specied in the following steps. Tighten remaining
fasteners according to chapter 14.1 Fastener Torque
Ratings.
Reassembly
1. Position the fan power card on the power card
mounting plate, and press onto the 4 plastic
standos.
2. Fasten 6 screws (T20). Torque to 2.27 Nm (20.1 lb-
in).
3. Attach the cables to the following fan power card
connectors:
3a MK600
3b MK602
3c MK802
3d MK803
3e MK1200
4. Route the cables through the cable retaining clips
on the mounting plate.
E1h–E4h Drive Disassembly a... Service Guide
MG94A502 Danfoss A/S © 02/2019 All rights reserved. 267
13 13

Table of Contents

Other manuals for Danfoss VLT AHF 005

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AHF 005 and is the answer not in the manual?

Danfoss VLT AHF 005 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AHF 005
CategoryDC Drives
LanguageEnglish

Related product manuals