6 Mechanical Installation Considerations
6.1 Storage
Store the drive in a dry location. Keep the equipment
sealed in its packaging until installation. Refer to
chapter 5.4 Ambient Conditions for recommended ambient
temperature.
Periodic forming (capacitor charging) is not necessary
during storage unless storage exceeds 12 months.
6.2 Lifting the Unit
Always lift the drive using the dedicated lifting eyes. To
avoid bending the lifting holes, use a bar.
WARNING
RISK OF INJURY OR DEATH
Follow local safety regulations for lifting heavy weights.
Failure to follow recommendations and local safety
regulations can result in death or serious injury.
•
Ensure that the lifting equipment is in proper
working condition.
•
See chapter 3 Product Overview and Features for
the weight of the dierent enclosure sizes.
•
Maximum diameter for bar: 20 mm (0.8 in).
•
The angle from the top of the drive to the
lifting cable: 60° or greater.
Illustration 6.1 Recommended Lifting Method
Mechanical Installation Con... Design Guide
MG06K102 Danfoss A/S © 03/2019 All rights reserved. 33