Object name Class Instance Attribute
Brake torque-2 100 175 100
Brake time-2 100 176 100
Language 100 177 100
User screen - top left 100 178 100
User screen - top right 100 179 100
User screen - bottom left 100 180 100
User screen - bottom right 100 181 100
Graph timebase 100 182 100
Graph maximum adjustment 100 183 100
Graph minimum adjustment 100 184 100
Mains reference voltage 100 185 100
Access code 100 186 100
Adjustment lock 100 187 100
Emergency run 100 188 100
Current calibration 100 189 100
Main contactor time 100 190 100
Bypass contactor time 100 191 100
Motor connection 100 192 100
Jog torque 100 193 100
Motor overload 100 194 100
Current imbalance 100 195 100
Undercurrent 100 196 100
Instantaneous overcurrent 100 197 100
Frequency 100 198 100
Heat sink overtemperature 100 199 100
Table 7.9 Class 100 Objects
7.3.2.2 Class 101 Objects (Read/Write)
Object name Class Instance Attribute
Excess start time 101 100 100
Input A trip 101 101 100
Motor thermistor 101 102 100
Starter communication 101 103 100
Network communication 101 104 100
Battery/clock 101 105 100
Low control volts 101 106 100
Comms timeout 101 107 100
Tracking gain 101 108 100
Tracking gain-2 101 109 100
Frequency detect 101 110 100
Bypass protection 101 111 100
Pedestal detect 101 112 100
Table 7.10 Class 101 Objects
7.3.2.3 Class 103 Objects (Read-only)
Object name Class Instance Attribute
Binary protocol version 103 100 100
Product type code 103 101 100
Minor software version 103 102 100
Major software version 103 103 100
Soft starter model 103 104 100
Parameter changed 103 105 100
Num parameter 103 106 100
Parameter value 103 107 100
Access type 103 108 100
Starter state 103 109 100
Warning 103 110 100
Initialized 103 111 100
Reserved 103 112 100
Parameters have changed 103 113 100
Phase sequence 103 114 100
Trip/warning code 103 115 100
Current 103 116 100
Current % of FLC 103 117 100
Motor 1 temperature 103 118 100
Motor 2 temperature 103 119 100
Power (W) 103 120 100
Power scale 103 121 100
% power factor 103 122 100
Voltage (refers to mains reference
voltage)
103 123 100
Phase 1 current 103 124 100
Phase 2 current 103 125 100
Phase 3 current 103 126 100
Phase 1 voltage (refers to mains
reference voltage)
103 127 100
Phase 2 voltage (refers to mains
reference voltage)
103 128 100
Phase 3 voltage (refers to mains
reference voltage)
103 129 100
Minor revision 103 130 100
Major revision 103 131 100
Table 7.11 Class 103 Objects
Packet Structures EtherNet/IP Module
18 Danfoss A/S © 05/2017 All rights reserved. MG17Q102
77

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Compact Starter MCD 201 and is the answer not in the manual?

Danfoss VLT Compact Starter MCD 201 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Compact Starter MCD 201
CategoryController
LanguageEnglish

Related product manuals