7.3.3.3 Status Codes for Acyclic Services
Status
code
Status name Comments
0x00 Success This code is returned after successful execution of the service, that is
When the register mapped for service Get attribute single is successfully read.
When the register mapped for service Set attribute single is successfully set.
0x03 Invalid parameter value
0x05 Path destination unknown The mapped register does not exist.
0x08 Service not supported The requested service is not available for this Object class/instance.
0x09 Invalid attribute value This code only applies to the service Set attribute single. It is returned if the value is out of range
for the mapped register.
0x0E Attribute not settable This code only applies to the service Set attribute single. It is returned if the mapped register is
read-only.
0x14 Attribute not supported The attribute specied in the request is not supported.
0x16 Object does not exist The object specied does not exist in the device.
Table 7.14 Status Codes, Get/Set Attribute Single
Packet Structures Installation Guide
MG17Q102 Danfoss A/S © 05/2017 All rights reserved. 21
7 7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Compact Starter MCD 201 and is the answer not in the manual?

Danfoss VLT Compact Starter MCD 201 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Compact Starter MCD 201
CategoryController
LanguageEnglish

Related product manuals