Table 258: Option:
14-55 Output Filter
Default value: [0] No filter
Change during operation: False
Select the type of connected output filter.
Table 259: Option:
For backwards compatibility only.
Sine-wave filter with feedback
Sine wave filter with feedback is selected.
This option is only valid for drives of the following enclosure sizes:
IP20, 3x380–480 V, enclosure sizes H6–H8.
4.11.7 14-6* Auto Derate
Parameter group for configuring automatic derating based on the output frequency of the drive.
14-61 Function at Inverter Overload
Change during operation: True
When the drive issues an inverter overload warning, select whether to continue and probably trip the drive or derate the output
current.
Table 260: Option:
14-63 Min Switch Frequency
Default value: [2] 2.0 kHz
Change during operation: False
Set the lowest switch frequency allowed by the application.
Table 261: Option:
AU363928304090en-000101 / 130R0982 | 137Danfoss A/S © 2021.07
Parameters
VLT® Flow Drive FC 111
Programming Guide