0 = Motor operating within thermal capacity (thermal model)
1 = Motor operating above thermal capacity (thermal model)
8.2.3.2 Bytes 2–3: Reserved
8.2.3.3 Bytes 4–7: Motor Current
Average rms current across all 3 phases. Measured current is shown as a 32-bit value to 2 decimal places.
10d (0x0A) = 0.10 A
3450d (0xD7A) = 34.50 A
68930d (0x10D42) = 689.30 A
8.2.3.4 Bytes 8–9: Trip Code
See the chapter Trip Codes.
8.2.3.5 Bytes 10–11: Reserved
8.3 Explicit Messaging (Acyclic Operation)
This section provides information on objects, instances, attributes, and services for acyclic operation (explicit messaging).
All data is in little endian format.
8.3.1 Identity Object (Class 0x01)
Table 5: Supported Attributes for Identity Objects
AN427641276310en-000101 / 175R1187 | 25Danfoss A/S © 2022.10
Packet Structures
EtherNet/IP Module