2-20 Release Brake Current
Range: Function:
0.00 A
*
[0.00 - 100 A]
Select motor current at which mechanical brake releases.
If start delay time has passed, and motor current is below
Release brake current
, frequency
converter trips.
2-22 Activating Mechanical Brake
Range: Function:
If the motor is stopped using ramp, the mechanical brake is activated when motor speed is less than
Active
Brake Speed
.
Motor is ramped down to stop in the following situations:
A start command is removed (stand by)
A stop command is activated
Quick-stop is activated (Q-stop ramp is used)
0 Hz
*
[0 - 400 Hz]
Select motor speed at which mechanical brake activates when ramping down.
Mechanical brake automatically activates if frequency converter trips or reports an alarm.
4. Parameter Descriptions VLT
p
Micro Drive FC 51
24
MG.02.C4.02 - VLT
p
is a registered Danfoss trademark
4

Other manuals for Danfoss VLT Micro Drive FC 51 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Micro Drive FC 51 Series and is the answer not in the manual?

Danfoss VLT Micro Drive FC 51 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT Micro Drive FC 51 Series
CategoryMedia Converter
LanguageEnglish

Related product manuals