RS-232/USB-Com Interfaces
46
QuickScan
TM
Lite QW2100
ENTER/EXIT PROGRAMMING MODE
ACK NAK Options
This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol.
When configured, the reader and/or host sends an “ACK” when it receives data properly, and
sends “NAK” when the data is in error.
Options are:
•Disable
Enable for label transmission — The reader expects an ACK/NAK response from the host
when a label is sent.
Enable for host-command acknowledge — The reader will respond with ACK/NAK
when the host sends a command.
Enable for label transmission and host-command acknowledge
$CR2AE00
ACK/NAK Protocol = Disable ACK/NAK
$CR2AE01
ACK/NAK Protocol = Enable for label transmission
$CR2AE02
ACK/NAK Protocol = Enable for host-command
acknowledge
$CR2AE03
ACK/NAK Protocol = Enable for label transmission and host-com-
mand acknowledge
DEFAULT

Table of Contents

Other manuals for Datalogic QuickScan Lite QW2100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Lite QW2100 and is the answer not in the manual?

Datalogic QuickScan Lite QW2100 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength650 nm
Sensor typeLaser
Read rate (max)400 reads/s
Yaw reading angle-70 - 70 °
Tilt reading angle-45 - 45 °
Pitch reading angle-65 - 65 °
Linear (1D) barcodes supportedEAN 5, EAN-13, EAN-8, GS1-128 (UCC/EAN-128)
2D (matrix & stacked) barcodes supportedNot supported
Standard interfacesUSB
Connectivity technologyWired
Input voltage5 V
Power consumption340 mA
Power source typeDC
Product colorBlack
Housing material-
International Protection (IP) codeIP42
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth65 mm
Width170 mm
Height70 mm
Weight119 g