Removal and Replacement
4-18
Printhead
Assembly
Inner
Bearing Plate
Screw
Assist
Roller
Platen
Block
4. Disconnect the Drive Motor Cable from the Power Supply PCB.
5. Remove the two Screws and Lock Washers that secure the Drive Motor then carefully
remove the Drive Motor.
Drive
Motor
Screws
Lock
Washers
Drive
Motor Cable
Isolator
Installation:
1. Carefully insert the motor’s gear into the drive gear train, rotating the Drive Motor so
that it rests flush against the Isolator, with gears meshed, aligned to the screw holes.