Site Preparations
The S5000 is suitable for installation as part of a Common Bond Network (CBN). It can be installed in:
network telecommunication facilities
data centers
other locations where the National Electric Code (NEC) applies
Topics:
Site Selection
Cabinet Placement
Storing Components
Site Selection
Dell EMC equipment is intended for installation in restricted access areas. A restricted access area can only be accessed by service
personnel by using a special tool, lock, key or other means of security and access is controlled by the authority responsible for the location.
Ensure that the area where you install your S5000 system meets the following safety requirements:
Near an adequate power source. Connect the system to the appropriate branch circuit protection as defined by your local electrical
codes.
Environmental temperature between 32° to 104°F (0° to 40°C).
Relative humidity that does not exceed 85 percent noncondensing.
In a dry, clean, well-ventilated and temperature-controlled room, away from heat sources such as hot air vents or direct sunlight.
Away from sources of severe electromagnetic noise.
Positioned in a rack or cabinet, or on a desktop with adequate space in the front, rear, and sides of the S5000 for proper ventilation
and access.
Cabinet Placement
Install the S5000 only in indoor cabinets designed for use in a controlled environment as described in Site Selection.
The cabinet must meet the following criteria:
Minimum cabinet size and airflow are according to the Electronic Industries Alliance (EIA) standard.
Storing Components
If you do not install your S5000 and components immediately, Dell EMC recommends properly storing the system and all optional
components until you are ready to install them.
NOTE:
ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground
strap when handling the S5000 and its accessories. After you remove the original packaging, place the S5000 and its
components on an anti-static surface.
1. Storage temperature must remain constant ranging from -4° to 158° F (-20°C to 70° C).
2. Store on a dry surface or floor, away from direct sunlight, heat, and air conditioning ducts.
3. Store in a dust-free environment.
5
14 Site Preparations