ASDA-A2 Chapter 12 Absolute System
12-2 Revision February, 2017
12.1 Backup Battery Boxes
12.1.1 Specifications
Precautions
Please thoroughly understand and observe the following safety precautions. Failure to observe
these precautions may void warranty! In order to prevent damage and danger, please use batteries
in accordance with the specified specification.
 Do not use the product in a potentially explosive environment. Install the product in a
clean and dry location free from corrosive and inflammable gases or liquids.
 Do not place the battery dispersedly to prevent short circuiting and accidents.
 Do not short circuit the positive pole and the negative pole of the batteries or install
batteries in reverse polarity.
 To prevent electric energy loss and lifetime reduction, it is recommended to use new
batteries only.
 Do not store batteries within an ambient temperature above +100°C. Failure to observe
this precaution may cause fire or explosion.
 The batteries are non-rechargeable. Do not charge the batteries or explosion may
result.
 Do not directly solder the battery surface.
Battery Specifications
Items Li/SOCl2 Cylindrical Battery
Type ER14505
Delta Model Number ASD-CLBT0100
International Standard Size AA
Nominal Voltage 3.6 V
Nominal Capacity 2700 mAh
Maximum Continuous Operating Current 100 mA
Maximum Pulse Current 200 mA
Dimensions (D x H) 14.5 x 50.5 mm
Weight Approx. 19 g
Operating Temperature -40 ~ +85°C