ASDA-A2 Chapter 4 Panel Display and Operation
4-10 Revision February, 2017
4.4.2 JOG Mode
When it is in Parameter Mode, select P4-05 and follow the setting method below for JOG operation.
(1) Press the SET Key to display the speed value of JOG. The default value is 20r/min.
(2) Press UP or DOWN Key to adjust the desired speed value of JOG. It is adjusted to 100r/min
in the example.
(3) Press the SET Key to display JOG and enter JOG mode.
(4) When it is in JOG Mode, press UP or DOWN Key to enable the servo motor in forward or
reverse direction. The servo motor stops running as soon as the user stops pressing the key.
JOG operation is working only when it is Servo ON.