ASDA-A2 Chapter 6 Control Mode of Operation
Revision February, 2017 6-51
motor operates according to the speed command. When S-T is ON, it goes back to the torque
mode again. Please refer to the introduction of single mode for DI signal and the selected
command of each mode.
6.5.3 Torque / Position Dual Mode
There are PT-T and PR-T in speed/position dual mode. The command source of the former one
comes from external pulse while the latter one comes from internal parameters (P6-00~P7-27).
Torque command could be issued by external analog voltage or internal parameters (P1-12~P1-
14). The switch of torque/position mode is controlled by T-P signal and the switch of PR-T mode is
controlled by DI signal, which is more complicated. The timing diagram is shown as below.
In torque mode (T-P is ON), the torque command is selected via TCM0 and TCM1. CTRG is not
working at the moment. When switching to position mode (T-P is OFF), since position command
has not been issued (needs to wait the rising edge of CTRG), the motor stops. The position
command is determined by POS0~POS5 and triggered by rising edge of CTRG. When T-P is ON,
it goes back to torque mode again. Please refer to the introduction of single mode for DI signal and
the selected command of each mode.

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
BrandDelta
ModelASDA-A2 Series
CategoryServo Drives
LanguageEnglish

Related product manuals