ASDA-A2 Chapter 9 Communications
9-4 Revision February, 2017
P3-01 BRT Transmission Speed
Address: 0302H
0303H
Operational
Interface
Panel / Software Communication
Related Section:
9.2
Default
0x0203
Control
Mode
ALL
Unit
bps
Range
0x0000 ~ 0x0405
Data Size
16-bit
Format
Hexadecimal
Settings
The setting of transmission speed is divided into Z, Y, X (hexadecimal):
0 Z Y X
Communication
Port
CAN
RS-232/485
Range 0 0~4 0 0~5
Definition of X setting value
0: 4800
1: 9600
2: 19200
3: 38400
4: 57600
5: 115200
Definition of Z setting value
0: 125 Kbit/s
1: 250 Kbit/s
2: 500 Kbit/s
3: 750 Kbit/s
4: 1.0 Mbit/s
NOTE
1If this parameter is set via CAN, only Z can be set and the others
remain.
2The communication speed of USB is 1.0 Mbit/s only and is
unchangeable.