ASDA-A2 Chapter 10 Troubleshooting
10-30 Revision February, 2017
AL023
:Early warning for overload
Turn DI.ARST on to clear the alarm
AL024
:Encoder initial magnetic field error
The alarm can be cleared after re-
power on.
AL025
:The internal of the encoder is in error
The alarm can be cleared after re-
power on.
AL026
:The encoder is in error
The alarm can be cleared after re-
power on.
AL027
:Encoder reset error
The alarm can be cleared after re-
power on.
AL028
:The encoder is over voltage or the internal
of the encoder is in error
The alarm can be cleared after re-
power on.
AL029
:Gray code error
The alarm can be cleared after re-
power on.
AL030
:Motor crash error
Turn DI.ARST on to clear the alarm
AL031
:Incorrect wiring of the motor power line U,
V, W, GND
The alarm can be cleared after re-
power on.
AL034
:Internal communication of the encoder is in
error
The alarm can be cleared after re-
power on.
AL035
:Encoder temperature exceeds the
protective range
The temperature sensor of motor
shall below 100
℃
. And the alarm
can be cleared after re-power on.
AL040
:Excessive deviation of full closed-loop
position control
Turn DI.ARST on to clear the alarm.
AL041
:The communication of linear scale is
breakdown
Turn DI.ARST on to clear the alarm.
AL042
:Analog input voltage error
Turn DI.ARST on to clear the alarm.
AL044
:Warning of servo drive function overload
Set P2-66 Bit4 to 1 and then re-power
on the servo drive.
AL045
:Wrong setting of E-gear ratio
The alarm can be cleared after
correctly setting up the parameter.
AL060
:The absolute position is lost
The alarm can be cleared after re-
power on.
AL061
:Encoder under voltage
Change the battery and AL.061 will be
cleared automatically.
AL062
:The multi-turn if absolute encoder
overflows
The alarm can be cleared after re-
power on.
AL067
:Encoder temperature warning
Turn DI.ARST on to clear the alarm.
AL068
:Absolute data transmitted via I/O is in error
The alarm can be cleared after re-
power on.
AL069
:Wrong motor type
Set P2-69 to 0 and then re-power on
the servo drive.

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
BrandDelta
ModelASDA-A2 Series
CategoryServo Drives
LanguageEnglish

Related product manuals