EasyManuals Logo
Home>Delta>Inverter>RPI M30A

Delta RPI M30A User Manual

Delta RPI M30A
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
Model Current Rating Wire size
RPI M30A_121 DC 30A 6 mm / 10 AWG
2
RPI M50A_120 DC 15A 4 - 6mm / 12 - 10 AWG
2
RPI M50A_122 DC 15A 4 - 6mm / 12 - 10 AWG
2
Table 4-5 Cable size
Figure 4-15 DC Wiring illustration
Figure 4-16 Communication module
DC wiring polarities are divided into positive and negative, which is shown
in Figure 4-15. The connection shall be coherent with the indication marked
on inverter.
PV-KBT4/6
PV-KST4/6
4.5 Communication Module Connections
Please refer to Figure 4-16 for the Communication Module illustration.
The module provides VCC, RS-485, dry contact, EPO, and Digital Input
terminals for different use.
** Please using diameter Φ3.5 ~ Φ4.9 cable wires. **
EPO*1 &
Digital Inputs*6
Dry Contact*2
VCC & RS-485
Terminal Resistor & VCC Switch