EasyManuals Logo
Home>Delta>DC Drives>VFD004EL21W-1

Delta VFD004EL21W-1 User Manual

Delta VFD004EL21W-1
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
Chapter 4 Parameters
VFD-EL-W
4-95
When the pressure sensor is set to 10 kg, Pr.10.49=1 and Pr.10.12=10.0% (that is, the physical quantity=1
kg), and if the set point=3 kg and feedback < 1 kg, then the AC motor drive follows the setting for Pr.10.20.
10.50
Number of Times of Restart after PID Fault
Settings 0–1000 times Default: 0
When you set Pr.10.20 =4, this parameter sets the number of times to restart when PID error occurs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD004EL21W-1 and is the answer not in the manual?

Delta VFD004EL21W-1 Specifications

General IconGeneral
BrandDelta
ModelVFD004EL21W-1
CategoryDC Drives
LanguageEnglish

Related product manuals