These settings can be used to signifi cantly change the operation of the heater. While useful for very specifi c requirements,
there is a much higher risk of User error and unintended consequences of changing these settings compared to the top-
level settings menu. It is recommended that these settings are only modifi ed by trained professionals.
To navigate to the Advanced Settings menu, from the home screen:
Press and hold Advance and Menu buttons for 5 seconds.
Each of the following headings relate to an item in the settings menu.
Temp Settings
Temp Units (Temperature Units)
This setting defi nes which temperature units are displayed on the heater. The default is °C, but °F can be
set. When °F is selected, the heater will convert °C values to °F and round to the nearest number.
Charging Settings
If the output of the storage heater is not able to deliver the required heat demand throughout the day, it is possible
to force the heater to store additional energy. This will manually adjust the charge calculation to store more electrical
energy during the charging period.
This setting displays the available charge times for the Heater to store o -peak energy. It is presented like the Timer
setup screen, but without a Target Temperature or Day Selection. This allows the Installer to set up to 4 charging On
and O times.
Charge Times
This setting displays the available charge times for the Heater to store o -peak energy. It is presented like the Timer
setup screen, but without a Target Temperature or Day Selection. This allows the Installer to set up to 4 charging On
and O times.
Default charge times (Standalone) are:
Period 1 00:00 - 00:00
Period 2 00:00 - 00:00
Period 3 00:00 - 00:00
Period 4 00:00 - 00:00
Charge times should remain at the default settings (as shown above) for twin supply installations. This setting
should only be used in single supply installations. Values entered here always take precedent.
Single Supply Charge Times - below is an example of how to set the o -peak times prior to midnight.
If the o peak times is between 23:30 and 06:30 then;
Period 1 00:00 - 06:30
Period 2 07:00 - 07:00
Period 3 07:00 - 07:00
Period 4 23:30 – 23:59
Advanced Settings
Service Settings
These items are for use by service personnel only. The settings e ect the accuracy and energy usage of the heater
and should only be modifi ed by a professional.
Room Temp (Temperature) O set
Allows the manual adjustment of electronic room thermostat reading by +/-3.0°C
Secondary Heater Mode
This setting modifi es the charge algorithm to prevent under-charging when enabled. If more than one
heater is installed in the same room, it is recommended that the smallest capacity heater(s) is set as a
Secondary. This is disabled by default.
Heat Source Setting
With this setting, it is possible to restrict use of peak rate energy for each of the following modes:
- Timer Mode
- Boost Mode
- Setback Mode
Factory Reset
This setting allows the User to restore the default values to all settings. Returning the product to the same state
that it left the factory.
NOTE:
Increased use of peak rate electricity could lead
to increased running costs