96
INM MTL SUM5 Rev 7
DRAFT - 09 June 2021 DRAFT - 09 June 2021
34.1 Environmental Specications
Temperature
Operating Temperature - 20 to + 60 Degrees C
Storage Temperature - 20 to + 80 Degrees C
Humidity 0 – 95% RH, Non Condensing
Protection
Annunciator front: IP40
Annunciator rear: IP20
Optional front IP54
EMC Compliance
IEC61326-1: 2013
Radiated RFI Immunity
IEC 61000-4-3
Conducted RFI Immunity
IEC 61000-4-6
Radiated Emissions
IEC 61000-6-3
Conducted Emissions
IEC 61000-6-3
Radiated Power Frequency Magnetic Field
IEC 61000-4-8
ESD Effects
IEC 61000-4-2
Surge Withstand – Oscillatory
ANSI C37.90.1
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4
Surge Immunity
IEC 61000-4-5
LV D
EN 61010-1-2010