3.7.5 Automatic upload
In the client mode (TCP client, UDP client, MQTT client, HTTP client), the gateway will automatically poll the instructions in the stored
instruction table and upload them to the server, and can choose the feedback format (Modbus RTU format or Modbus TCP format) and the
instruction polling interval (0-65535ms) according to your needs
Refer to "Configurable Gateway-Instruction Storage Instructions" for instruction pre-storage, and automatically upload the configuration
of the host computer/web page: