In order to avoid problems such as server search failure and inability to open web pages in the actual application process, it is
recommended to check the relevant settings of the computer first.
1 Turn off your computer's firewall and anti-virus software
2 Configure the NIC to which the device is connected
3 This case is for the device directly connected to the computer test, you need to configure the computer as a static IP (the
computer is directly connected to the device, there is no router to assign, the computer cannot obtain the IP address), and the use of switches or
routers needs to ensure that the device and the computer are in the same network segment (for example: 192.168.3.xxx)
4
In this case, the static IP address of the computer is 192.168.3.4 (the same CIDR block as the device), the subnet mask is
255.255.255.0, and the default gateway is 192.168.3.1
4.3.2 Radio Ethernet default parameters
project
Default parameters
IP address
192.168.3.7
Default local port
8887
Subnet mask
255.255.255.0
Default gateway
192.168.3.1
Default working mode
TCP Server
Serial port baud rate
115200Modification is not recommended
Serial port parameters
8 / None / 1Modification is not recommended
4.3.3 Network connectivity test
After the above operation steps, follow the factory default parameters of the device and perform the following operations to achieve
network connection
The procedure is as follows
1Open the Test TCP/IP Debugging Assistant software
2In the "Network Settings" area, select TCP Client Mode, the remote host address corresponds to (the default local IP
of the device: 192.168.3.7), and the remote host port corresponds to the factory port 8887 of the device, click Connect