Cleaning and maintenance
09/2011 1002410-04 Operating instructions – 45
5.8.2 Low pressure lamps
y Replace faulty UV low pressure lamps immediately.
y Always replace the entire set of lamps after the specified operating time.
Turn 90° and carefully remove from the socket.
UV low pressure lamps possess a reflector which directs the light out-
wards. The lamps must be mounted in such a way that the rear side of
the reflector is located on the device side.
Push the pins vertically into the socket from above.
Turn the lamp 90°.
The lettering must be oriented towards the outside (i.e. towards the tan-
ning room or towards the user).