XT Series DISK RECORDER - Technical Reference
EVS Broadcast Equipment SA - Nov 2005
Issue 3.0
20
3.6 RS422 connector of the Remote control
panel
The RS 422 cable of the Remote control panel must be wired PIN TO PIN
following the above diagram. Use shielded cable to avoid electromagnetic
interference on long distances.
!
Important note: The Reset command from the Remote is sent through the Pin n°5 of
RS422 connector. This function should be disabled when the controller on RS422 #1
is not an EVS controller (refer to the PC board description on page 55 of this manual)