INDIRECT TILTING PANS, ELECTRIC TYPE
ˆPMKIE100˜ ˆPMKIE150˜ ˆPMKIE200˜ ˆPMKIE300˜ ˆPMKIE500˜
WARNING! :
The appliance must be disconnected from the power supply during cleaning,
maintenance and replacement of internal components.
WARNING! :
When cleaning the appliance never use direct jets of water to prevent infiltration of
the liquid and damage to components.
WARNING! :
Possibility of slippery floor in the areas adjacent to the appliance.
WARNING! :
If the power cable is damaged, it must be replaced by the manufacturer or by its
technical assistance service or by a similarly qualified person in order to avoid any
risk.
1.4 CONSTRUCTION
− Main structure in AISI 430 with 4 adjustable height feet.
− Panels in stainless steel AISI 304, thickness 10-12/10.
− Cooking vat in stainless steel AISI 316, thickness 20/10.
− Lid in stainless steel, hinged and spring balanced in all opening positions.
− Jacket and lining in stainless steel AISI 304, thickness 15-20/10.
− Heating system comprising shielded heating elements made from “Incoloy-800” alloy with boiler and steam
circulation, controlled by electromechanical thermostat and by pressure switch to prevent steam outlet
from the safety valve and unnecessary power waste.
− Jacket pressure is controlled by means of pressure switch and safety valve; the appliance is equipped with
an breather valve eliminating air from inside the jacket to speed up heating using saturated steam,
vacuum breaker valve and analogic pressure gauge.
− The appliance is equipped with :
− Three-position selector
− Operating thermostat for temperature adjustment inside the cooking vat.
− Selector for tilting and return of the pan.
− Lamp green light indicates when the unit is energized.
− Lamp orange light indicates when the heating is in function.
− Lamp orange light indicates the lowest water level in jacket .
− Lamp red light indicates the heating interruption in case of water missing in jacket.
− Manual tap (hot / cold water) to fill the vat.
− Front tap level control jacket.
− Analogical pressure gauge .
− Jacket safety valve.
− Air elimination valve.
− Vacuum breaker valve.
− Heating interruption in case of water missing in jacket.
− Safety thermostat to interrupt operation automatically in case of failures.
− Heating interruption during vat tilting