INSTRUCTION MANUAL FOR INSTALLATION, MAINTENANCE AND
USE Rev−12
PMKIE−DIMU−GB−12
5
GB
INDIRECT TILTING PANS, ELECTRIC TYPE
ˆPMKIE100˜ ˆPMKIE150˜ ˆPMKIE200˜ ˆPMKIE300˜ ˆPMKIE500˜
WARNING! :
The appliance must be disconnected from the power supply during cleaning,
maintenance and replacement of internal components.
WARNING! :
When cleaning the appliance never use direct jets of water to prevent infiltration of
the liquid and damage to components.
WARNING! :
Possibility of slippery floor in the areas adjacent to the appliance.
WARNING! :
If the power cable is damaged, it must be replaced by the manufacturer or by its
technical assistance service or by a similarly qualified person in order to avoid any
risk.
1.4 CONSTRUCTION
Main structure in AISI 430 with 4 adjustable height feet.
Panels in stainless steel AISI 304, thickness 10-12/10.
Cooking vat in stainless steel AISI 316, thickness 20/10.
Lid in stainless steel, hinged and spring balanced in all opening positions.
Jacket and lining in stainless steel AISI 304, thickness 15-20/10.
Heating system comprising shielded heating elements made from “Incoloy-800” alloy with boiler and steam
circulation, controlled by electromechanical thermostat and by pressure switch to prevent steam outlet
from the safety valve and unnecessary power waste.
Jacket pressure is controlled by means of pressure switch and safety valve; the appliance is equipped with
an breather valve eliminating air from inside the jacket to speed up heating using saturated steam,
vacuum breaker valve and analogic pressure gauge.
The appliance is equipped with :
Three-position selector
Operating thermostat for temperature adjustment inside the cooking vat.
Selector for tilting and return of the pan.
Lamp green light indicates when the unit is energized.
Lamp orange light indicates when the heating is in function.
Lamp orange light indicates the lowest water level in jacket .
Lamp red light indicates the heating interruption in case of water missing in jacket.
Manual tap (hot / cold water) to fill the vat.
Front tap level control jacket.
Analogical pressure gauge .
Jacket safety valve.
Air elimination valve.
Vacuum breaker valve.
Heating interruption in case of water missing in jacket.
Safety thermostat to interrupt operation automatically in case of failures.
Heating interruption during vat tilting