14-7. Simple remote controller
DIP switch
SW1 Prohibited
SW2 Dual remote controller setting
SW3 °F/°C switch
SW4 Prohibited
SW5 Prohibited
SW6 Prohibited
¢
Switch location
¢
DIP switch setting
SW2: Dual remote controller setting
Set the remote controller SW2 according to the following table.
Number of remote controller
Primary unit Secondary unit
Factory setting
SW2 SW2
1 (Normal) OFF — ♦
2 (Dual) OFF ON
1 231 23
1 2 3
Indoor unit
Remote controller cable
Primary unit
Secondary
unit
Remote controller
SW3: Switching temperature unit °F / °C
Displayed temperature unit can be switched between Fahrenheit (°F) and Celsius (°C).
SW3 Fahrenheit (°F) / Celsius (°C) Factory setting
OFF °C
ON °F ♦
- 157 -
14-7. Simple remote controller 14. Function settings
MULTI TYPE
2, 3, 4 ROOMS TYPE
MULTI TYPE
2, 3, 4 ROOMS TYPE