6. Capacity table
6-1. Combinations
¢ Model: AOU18RLXFZ
Cooling
1) Non-ducted
Combination of indoor unit
Rated capacity for each in-
door unit (kBtu/h)
Maximum capacity for each
indoor unit (kBtu/h)
Total capacity
(kBtu/h)
Input power (kW)
Room 1 Room 2 Total Room 1 Room 2 Room 1 Room 2 Min. Rated Max. Min. Rated Max.
7 7 14 7.05 7.05 8.70 8.70 6.10 14.10 17.40 0.50 1.30 1.64
7 9 16 7.09 9.11 8.66 11.14 6.10 16.20 19.80 0.50 1.44 1.81
7 12 19 6.63 11.37 7.74 13.26 6.10 18.00 21.00 0.50 1.43 2.06
9 9 18 9.00 9.00 10.50 10.50 6.10 18.00 21.00 0.50 1.44 2.06
9 12 21 7.71 10.29 9.00 12.00 6.10 18.00 21.00 0.50 1.44 2.06
2) Ducted
Combination of indoor unit
Rated capacity for each in-
door unit (kBtu/h)
Maximum capacity for each
indoor unit (kBtu/h)
Total capacity
(kBtu/h)
Input power (kW)
Room 1 Room 2 Total Room 1 Room 2 Room 1 Room 2 Min. Rated Max. Min. Rated Max.
7 9 16 7.09 9.11 8.66 11.14 6.10 16.20 19.80 0.50 1.49 1.86
7 12 19 6.63 11.37 7.74 13.26 6.10 18.00 21.00 0.50 1.48 2.11
9 9 18 9.00 9.00 10.50 10.50 6.10 18.00 21.00 0.50 1.49 2.14
9 12 21 7.71 10.29 9.00 12.00 6.10 18.00 21.00 0.50 1.49 2.14
NOTES:
Specifications are based on the following conditions.
• Power source of specifications: 230 V
• 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h
• 2 indoor units should be connected.
• Cooling: Indoor temperature of 80 °FDB (26.7 °CDB)/67 °FWB (19.4 °CWB), and outdoor tem-
perature of 95 °FDB (35 °CDB)/75 °FWB (23.9 °CWB).
• Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit—Indoor unit]
• The total ability of connected indoor units is from 14,000 Btu up to 21,000 Btu.
• Non-Ducted system combinations input are based on wall mount models. The input of combina-
tions including cassette models may be a little higher.
• Ducted system combinations capacities are based on slim duct units excepting 7,000-Btu mod-
els. 7,000 Btu models are based on wall mount models.
- 183 -
6-1. Combinations 6. Capacity table
OUTDOOR UNIT
AOU18RLXFZ
OUTDOOR UNIT
AOU18RLXFZ