52 Operating Manual
RX4770 M2
Hardware installation
5.4 Connecting the server to the mains
V CAUTION!
The server is automatically set to a mains voltage in the range
100 - 240 V or 200 – 240 V (depending on PSU model used). You may
only operate the server if its rated voltage range corresponds to the local
mains voltage.
5.4.1 Installation requirements
The power subsystem consists of:
Power supply modules (PSU)
A power distribution board (PDB)
The power supply subsystem can support up to 4 PSUs which all connect to the
PDB. The total system is rated 100 - 240 V, 24 - 16 A, 50 - 60 Hz or 200 – 240 V,
20 A (depending on PSU model used, refer to your system’s rating plate).The
minimum system configuration requires installation of at least two PSUs. The
PSU is considered hot-swappable. The system can be configured to support
*True AC redundancy or non-AC redundancy.
I *True AC redundancy is recommended for systems used for critical
business applications. This will result in the system to continue operation
during a power failure as the redundant part of the subsystem is plugged
into a separate AC source (e.g. uninterruptable power supply (UPS)).
I Refer to tables below for maximum DC loading for both AC redundant
and AC non redundant configurations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX4770 M2 and is the answer not in the manual?

Fujitsu PRIMERGY RX4770 M2 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX4770 M2
CategoryServer
LanguageEnglish

Related product manuals