EasyManua.ls Logo

Furuno CH-500 - Page 102

Furuno CH-500
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDIX 1 MENU TREE
Range Settings
HOR. (All defaults shown below)
m: 20, 40, 60, 80, 100, 120, 160, 200, 250, 300, 400, 500, 600, 800, 1200
ft: 40, 80, 120, 200, 300, 400, 500, 600, 700, 800, 1000, 1500, 2000, 2500, 3500
fm: 10, 20, 30, 40, 60, 80, 100, 120, 140, 160, 200, 250, 300, 400, 500
HR: 10, 20, 40, 60, 80, 100, 120, 140, 160, 200, 250, 300, 400, 500, 700
pb: 10, 20, 40, 60, 80, 100, 120, 140, 160, 200, 250, 300, 400, 500, 700
VERT (All defaults shown below)
m: 10, 20, 30, 40, 60, 80, 100, 120, 160, 200, 250, 300, 400, 500, 600
ft: 30, 60, 90, 120, 150, 200, 250, 300, 400, 500, 600, 800, 1000, 1500, 2000
fm: 10, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160, 200, 250, 300, 400
HR: 10, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160, 200, 250, 300, 400
pb: 10, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160, 200, 250, 300, 400
ES (All defaults shown below)
m: 10, 20, 30, 40, 60, 80, 100, 120, 160, 200, 250, 300, 400, 500, 600
ft: 30, 60, 90, 120, 150, 200, 250, 300, 400, 500, 600, 800, 1000, 1500, 2000
fm: 10, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160, 200, 250, 300, 400
HR: 10, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160, 200, 250, 300, 400
pb: 10, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160, 200, 250, 300, 400
Train Speed Setting
6º (Off, On )
12º (Off, On )
15º (Off, On )
18º (Off, On )
21º (Off, On )
24º (Off, On )
Color Settings (Opens Color Palette)
System Backup (No , Internal)
Load Backup Data (No , Load Internal Data)
Preset Backup (No , Internal)
Load Preset Data (No , Load Internal Data)
Draught Offset
Draught (0.0 m to 60.0 m; default: 0.0 m )
Hull Unit Stroke (0 mm to 400 mm; default 400 mm )
TX Frequency Offset
FREQ. Shift (Range and default dependent on transducer)
Audio
Audio FREQ. (0.90 kHz to 1.20 kHz; default: 1.00 kHz )
Bandwidth (Wide, Std. , Narrow)
Harmonic Pattern (1 , 2, 3)
Auto Filter (Off, On)
Tests (Starts diagnostic test)
Test Pattern (Starts LCD test)
NMEA Port Monitor (Starts port monitor)
Simulation
Simulation Mode (No , Load Internal Data)
Restore Initial Settings (No , Yes)
Language Settings (Japanese, English , Thai, Vietnamese, Chinese, Spanish, Indonesian,
Malay, Burmese, French, Norwegian, Italian)
(Continued from previous page)
AP-6

Table of Contents

Other manuals for Furuno CH-500

Related product manuals