APPENDIX 3 RA/IF BOARD JUMPER
VALUES
The values for each jumper block on the RA/IF board (24P0140) are shown below.
CH1/CH2 signal settings
Input bypass settings (CH2 only)
J1/J8 HD-TERM
1-2
1.2 kΩ
2-3
OFF
J2/J9 HD-PULL UP
1-4
5V IN
2-5
OC (560Ω)
3-6
OC (1 kΩ)
J3/J16 VID-TERM
1-5
75Ω
2-6
50Ω
3-7
1.2 kΩ
4-8
100 kΩ
J4/J12 HD-POLARITY
1-2
NORMAL
2-3
REVERSE
J5/J18 BP-TERM
1-2
1.2 kΩ
2-3
OFF
J6/J19 BP-PULL UP
1-4
5V IN
2-5
OC (560Ω)
3-6
OC (1 kΩ)
J10/J22 TRG-TERM
1-5
50Ω
2-6
75Ω
3-7
180kΩ
4-8
1.2 kΩ
J13/J24 BP-PULSE NUM
1-2
2048
2-3
1024
J7/J11 HD-INTERFACE
1-2
ADJUST
2-3
BYPASS
J14/J15 VID-INTERFACE
1-2
ADJUST
2-3
BYPASS
J17/J20 BP-INTERFACE
1-2
ADJUST
2-3
BYPASS
J21/J23
1-2
ADJUST
2-3
BYPASS