FELCOM 82
H3-6
2.4 Gyro setting
The communication unit has a built-in gyro I/F board, 64P1106, identical to the one
used in Furuno large radars. The board must be set up according to the type of the gyro
connected.
2.4.1 Switch and Jumper Setting
The default settings are shown in shaded cell of each setting item. (Turn off the unit to
change the settings.)
1) Gyro type
Gyro Type SW1 #4 SW1 #5 SW1 #6 JP1
AC synchro OFF OFF OFF #1, #2, #3
DC synchro OFF OFF OFF #2, #3, #4
DC step ON OFF OFF #4, #5, #6
Full-wave pulsating current OFF ON OFF #4, #5, #6
Half-wave pulsating current ON ON OFF #4, #5, #6
2) Frequency
Frequency SW1 #7 SW1 #8 Remarks
50/60 Hz OFF OFF AC synchro pulsating current
400 Hz ON OFF AC synchro pulsating current
500 Hz OFF ON AC synchro pulsating current
DC ON ON DC synchro, DC step
GYRO I/F Board
(64P1106)
Default setting
-Type : AC synchro
-Frequency : 50/60 Hz
-Rotor Voltage : 60 VAC to 135 VAC
-Stator Voltage : 60 VAC to 135 VAC
-Gear Ratio : 360X
-Supplied Power : 30 VAC to 135 VAC