190-01182-02 GTR 225/GNC 255 TSO Installation Manual
Rev. F Page D-4
NOTES
Figure D-2 GTR/GNC Typical Installation
Sheet 2 of 2
ALL WIRES 24 AWG OR LARGER UNLESS OTHERWISE SPECIFIED.
GROUND DESIGNATIONS: SHIELD BLOCK GROUND AIRFRAME GROUND
AT THE GTR/GNC, CONNECT SHIELD GROUNDS TO THE CONNECTOR BACKSHELL - THE SHIELD
TERMINATION LEADS SHOULD BE LESS THAN 3.0". CONNECT OTHER END OF THE SHIELD PER THE
REMOTE EQUIPMENT INSTALLATION REQUIREMENTS.
SEE FIGURE D-3 FOR POWER AND GROUND WIRING DETAILS.