190-01182-02 GTR 225/GNC 255 TSO Installation Manual
Rev. F Page D-21
NOTES
Figure D-12 GNC - Parallel Slip Code DME Tuning Interconnect
ALL WIRES 24 AWG OR LARGER UNLESS OTHERWISE SPECIFIED.
REFER TO MANUFACTURER’S DOCUMENTATION FOR COMPLETE PINOUT AND INTERCONNECT
INFORMATION. PINOUTS OF OTHER UNITS SHOWN FOR REFERENCE ONLY.
THE GNC SHOULD BE CONFIGURED TO OUTPUT SLIP CODE DME TUNING DATA FOR PROPER OPERATION
IN THIS CONFIGURATION. SEE SECTION 6 FOR CONFIGURATION SETTINGS.
FOR DUAL GNC INTERFACES TO THE DME, IT MAY BE NECESSARY TO INSTALL A TOGGLE SWITCH FOR
THE ”DME COMMON” INPUT. INSTALL SWITCH AS SHOWN FOR KING SERIAL PANEL DME INTERCONNECT.
PARALLEL SLIP
CODE TUNED DME
BENDIX/KING
KN 65
P651
GNC
PAR DME 1MHZ-A
PAR DME 1MHZ-B
PAR DME 1MHZ-C
PAR DME 1MHZ-D/SERIAL DME ON
PAR DME 100KHZ-A/SERIAL DME HOLD
PAR DME 100KHZ-B
PAR DME 100KHZ-C
DME COMMON
PAR DME 100KHZ-D
PAR DME 50KHZ
45
46
47
33
37
39
40
41
43
42
14
15
16
17
32
33
34
22
36
35
M0
M1
M2
M3
K0
K1
K2
DME COMMON
K50
K3
3
P2002
3