3-232 UR FAMILY – COMMUNICATIONS GUIDE
TICS CONFORMANCE STATEMENT CHAPTER 3: IEC 61850 COMMUNICATION
3
3.8 TICS conformance statement
A Technical Issue Implementation Conformance Statement (TICS) is required under IEC 61850.
This section provides a template for the TICS. According to the UCA International Users Group (UCAIug) Quality Assurance
Program (QAP), the TICS is a required conformance test and is referenced on the certificate. This section applies to URs with
firmware versions 7.30 and later.
The tables outline applicable mandatory technical issues (Tissues).
Y — The server has implemented the Tissue
ni — No impact on testing
na — Not applicable if the server does not support the corresponding ACSI service(s)
Tissues 675, 735, 772, 775, 776, and 878 are not relevant for conformance testing.
Notes follow the tables, which are for Edition 2.
Table 3-236: Part 6 Tissues
Table 3-237: Part 7 Tissues
Part 6 Tissue Description Implemented by server?
658 Tracking related features na
663 FCDA element cannot be a "functionally constrained logical node" Y
668 Autotransformer modeling na
687 SGCB ResvTms Y
719 ConfDataSet - maxAttributes definition is confusing Y
721 Log element name na
768 bType VisString65 is missing na
779 Object references Y
788 SICS S56 from optional to mandatory na
789 ConfLdName as services applies to both server and client
(supportsLdname)
Y
804 valKind and IED versus System configuration (valimport) Y
806 Max length of log name inconsistent between -6 and -7-2 na
807 Need a way to indicate if "Owner" present in RCB Y
823 ValKind for structured data attributes Y
824 Short addresses on structured data attributes na
825 Floating point value na
845 SGCB ResvTms Y
853 SBO and ProtNs Y
855 Recursive SubFunction na
856 VoltageLevel frequency and phases na
857 Function/SubFunction for ConductingEquipment na
886 Missing 8-1 P-types na
901 tServices as AP or as IED element Y
936 SupSubscription parameter usage is difficult Y
1175 IPv6 address lowercase only na
Part 7 Tissue Description Implemented by server?
Part 7-1
828 Data model namespace revision IEC 61850-7-4:2007[A] Y