NX-4 Control
Page 9
CHANGING USER CODES:
1. Enter [r]-[5]-[master code]. The "Ready" LED will flash.
2. Enter the 2 digit user number (always 2 digits such as "03" for user 3). The "Ready" LED will illuminate
steady.
3. Enter the new user code designated for that individual. The "Ready" LED will flash indicating that the code
was accepted. If it rejects the code, the sounder will beep 3 times. Note for NX1300 Series LED Keypad
:
The zone lights will illuminate specifying the first digit of the “user code”. (Lights 1-8 on = code is blank; lights
1-8 off = “0"; lights 1 and 8 = “9".) Use the up and down scroll keys to view the next digit or enter a new 4-
or 6-digit “user code”. While using the scroll keys you can change any digit by entering a new digit. This will
advance you to the next digit.
4. If another user code needs to be programmed, return to step 2.
5. Press [#] while the "Ready" LED is flashing to exit the User Code Programming Mode.
ASSIGNING AUTHORITY LEVEL:
1. Enter [r]-[6]-[master code]. The "Ready" LED will flash.
2. Enter [2 digit user number] (always 2 digit such as 03 for user 3). The "Ready" LED will illuminate steady and
the "Instant" LED will flash
3. Refer to this chart for the description of each LED. Turn the LED on for the features that you desire.
LED
ATTRIBUTES IF LED 8 IS OFF
LED
ATTRIBUTES IF LED 8 IS ON
1
Reserved
1
Activate output #1
2
Arm Only
2
Activate output # 2
3
Arm Only After Close Window
3
Reserved
4
Master arm/disarm (can program other codes)
4
Reserved
5
Arm/disarm code
5
Arm/disarm
6
Allowed to bypass zones (see location 23)
6
Bypass Zones
7
Code will send open / close reports
7
Open / Close Reporting
8
If this LED is on, LEDs 1-7 will use the chart to the
right
8
If this LED is off, LEDs 1-7 use the chart to the
left
4. Enter [r] [r]. This step returns you back to step 2 above. At this point you may enter another user number
to assign attributes for. You may continue this procedure until you have assigned authority levels to all user
numbers - or - you may press [#] key to exit the Assigning Authority Level Program.
[r]-[9]-[8]
Pressing [r]-[9]-[8] while the system is disarmed will cause the control to do a callback for a download.
NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [r]-[9]-[8] IF ENABLED IN LOCATION 41,
PAGE 19.
[r]-[9]-[9]
Pressing [r]-[9]-[9] while the system is disarmed will cause the control panel to seize the phone line for a
download. NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [r]-[9]-[9] IF ENABLED IN
LOCATION 41, PAGE 19.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-4 and is the answer not in the manual?

GE NetworX NX-4 Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Operating Environment IconOperating Environment
loop resistance300 Ohms Maximum
loop response500mS
operating temperature32 to 120 degrees F
Weight and Dimensions IconWeight and Dimensions
led keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
nx-148e lcd keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
metal enclosure dimension9.25" Wide, 8.25" High, 3.50" Deep