NX-4 Control
Page 33
APPENDIX 1 REPORTING FIXED CODES IN CONTACT ID AND SIA
The table below list the event codes sent for the following reports (if enabled) when using CONTACT ID or
SIA formats.
REPORT
CONTACT ID SIA
MANUAL TEST 601 RX
AUTOTEST 602 RP
OPEN (user number) 401 OP
CLOSE (user number) 401 CL
CANCEL (user number) 406 OC
DOWNLOAD COMPLETE 412 RS
START PROGRAM 627 LB
END PROGRAM 628 LX
RECENT CLOSE (user number) 401 CR
EXIT ERROR (user number) 457 EE
EVENT LOG FULL 605 JL
FAIL TO COMMUNICATE 354 RT
EXPANDER TROUBLE (device number) 333 ET
EXPANDER RESTORE (device number) 333 ER
SIREN TAMPER (device number) 321 YA
SIREN RESTORE (device number) 321 YH
AUX POWER OVER CURRENT (device number) 312 YP
AUX POWER RESTORE (device number) 312 YQ
LOW BATTERY (device number) 309 YT
LOW BATTERY RESTORE (device number) 309 YR
AC FAIL (device number) 301 AT
AC RESTORE (device number) 301 AR
BOX TAMPER (device number) 137 TA
BOX TAMPER RESTORE (device number) 137 TR
KEYPAD TAMPER 137 TA
KEYPAD PANIC (audible) 120 PA
KEYPAD PANIC (silent) 121 HA
DURESS 121 HA
KEYPAD AUXILIARY 1 110 FA
KEYPAD AUXILIARY 2 100 MA
RF SENSOR LOST (zone number) 381 *T
RF SENSOR RESTORE (zone number) 381 *R
SENSOR LOW BATTERY (zone number) 384 XT
SENSOR BATTERY RESTORE (zone number) 384 XR
ZONE TROUBLE (zone number) 380 *T
ZONE TROUBLE RESTORE (zone number) 380 *R
ZONE TAMPER (zone number) 137 TA
ZONE TAMPER RESTORE (zone number) 137 TR
ZONE BYPASS (zone number) 570 *B
BYPASS RESTORE (zone number) 570 *U
THE NUMBER IN PARENTHESES FOLLOWING THE EVENT IS THE NUMBER THAT WILL BE REPORTED AS THE
ZONE NUMBER. IF THERE ARE NO PARENTHESES, THE ZONE WILL BE A0". SEE PAGE 35 FOR THE DEVICE
NUMBERS.
* The character transmitted in this slot will be the first character from the event code of the zone that is
bypassed or in trouble. (See locations 110 - 141)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-4 and is the answer not in the manual?

GE NetworX NX-4 Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Operating Environment IconOperating Environment
loop resistance300 Ohms Maximum
loop response500mS
operating temperature32 to 120 degrees F
Weight and Dimensions IconWeight and Dimensions
led keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
nx-148e lcd keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
metal enclosure dimension9.25" Wide, 8.25" High, 3.50" Deep