NX-4 Control
Page 26
PROGRAMMING WORKSHEETS
? Factory defaults for segments are in bold italics text. Some locations are reserved and have
been intentionally omitted.
LOC
PG
DESCRIPTION
DEFAULT
PROGRAMMING DATA
0
12
PHONE #1
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
1
12
PHONE #1, ACCOUNT CODE
10 - 10 - 10 - 10 - 10 - 10
_ _ _ _ _ _
2
12
PHONE #1, REPORTING FORMAT
0
_
3
12
PHONE #1, DIAL ATTEMPTS
BACKUP CONTROL
8
0
_
_
PHONE #1, SELECTING EVENTS TO REPORT TO PHONE #1
Segment #1 (Circle Numbers To Program)
Segment #2 (Circle Numbers To Program)
4
13
1
2
3
4
5
6
7
8
Alarms and Restores
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure or Low Battery)
Siren
Test Reports
Program, Download, & Log Full
1
2
3
4
5
6
7
8
Tampers
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble
Failure To Communicate
Reserved
Reserved
6
14
PHONE #2
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
7
14
PHONE #2, ACCOUNT CODE
10 - 10 - 10 - 10 - 10 - 10
_ _ _ _ _ _
8
14
PHONE #2, REPORTING FORMAT
0
_
9
14
PHONE #2, DIAL ATTEMPTS
BACKUP CONTROL
8
0
_
_
PHONE #2, SELECTING EVENTS TO REPORT TO PHONE #2
Segment #1 (Circle Numbers To Program)
Segment #2 (Circle Numbers To Program)
10
14
1
2
3
4
5
6
7
8
Alarms and Restores
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure or Low Battery)
Siren
Test Reports
Program, Download, & Log Full
1
2
3
4
5
6
7
8
Tampers
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble
Failure To Communicate
Reserved
Reserved
12
15
PHONE #3
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
13
15
PHONE #3, ACCOUNT CODE
10 - 10 - 10 - 10 - 10 - 10
_ _ _ _ _ _
14
15
PHONE #3, REPORTING FORMAT
0
_
15
15
PHONE #3, DIAL ATTEMPTS
BACKUP CONTROL
8
0
_
_
PHONE #3, SELECTING EVENTS TO REPORT TO PHONE #3
Segment #1 (Circle Numbers To Program)
Segment #2 (Circle Numbers To Program)
16
15
1
2
3
4
5
6
7
8
Alarms and Restores
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure or Low Battery)
Siren
Test Reports
Program, Download, & Log Full
1
2
3
4
5
6
7
8
Tampers
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble
Failure To Communicate
Reserved
Reserved

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-4 and is the answer not in the manual?

GE NetworX NX-4 Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Operating Environment IconOperating Environment
loop resistance300 Ohms Maximum
loop response500mS
operating temperature32 to 120 degrees F
Weight and Dimensions IconWeight and Dimensions
led keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
nx-148e lcd keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
metal enclosure dimension9.25" Wide, 8.25" High, 3.50" Deep