SIA SYSTEM REQUIREMENTS (ANSI-SIA CP-01)
To meet SIA CP-01 requirements –
Minimum System Requirements: 1 control panel; 2 keypads
Remote arming shall NOT be enabled in SIA classified installations.
Off-premise transmission must be in the SIA format.
The Abort window and Entry Delay must not exceed 1 minute.
CAUTION – A call waiting cancel on a non-call waiting line will prevent successful connection to the central station.
CP-01 Feature
Description
Feature Description
as shown in manual
Program
Loc
Seg / Opt
Factory
Default
CP-01 Required
Setting
Exit Time Exit 1 Delay 24 2 60 45 – 240 sec.
Exit 2 Delay 24 4 60 45 – 240 sec.
Progress Annuncation / Disable
– for Silent Exit
Silent Keypad Option 9 3 2 All annunciators enabled Allowed
(individual keypads may be disabled)
Exit Time Restart This feature is non-programmable in the panel. Enabled
Auto Stay Arm on Unvacated
Premises
Auto Bypass 23 1 / 3 Enabled Enabled
Exit Time and Progress
Annunciation / Disable
– for Remote Arm
This feature is non-programmable in the panel. -- Exit time and progress are always
enabled.
Enabled (may be disabled for remote arming)
Entry Delay(s) Entry 1 Delay 24 1 30 30 – 240 sec.
Entry 2 Delay 24 3 30 30 – 240 sec.
Abort Window
– for Non-Fire Zones
Dialer Delay 40 8 30 Enabled
(may be disabled by zone/ zone
type)
Abort Window Time
– for Non-Fire Zones
Dialer Delay 40 8 30 15 – 45 sec.
NOTE:
Combined
Abort
window and
Entry Delay
must not
exceed 1
minute.
Abort Annunciation This feature is non-programmable in the panel. -- Flashing Cancel LED goes off when
disarming.
Enabled
Cancel Annunciation Cancel 23 3 / 6 Enabled Enabled
Duress Feature Duress 44 Disabled Disabled
Cross Zoning 2 Trips on Cross Zone 37 5 / 4 Disabled Required
Keypad sounds on Cross Zone trip 39 5 Disabled
Zone Type Characteristic 111 3 / 4 Disabled
Programmable Cross Zoning Time Cross Zone Time 40 6 5 minutes Allowed
Swinger Shutdown Swinger Shutdown Count 38 n/a Enabled for 1 trip For all non-fire zones, shut down at 1–2 trips
Swinger Shutdown Disable Swinger Shutdown Count 38 n/a Enabled for 1 trip Allowed
Fire Alarm Verification Fire Alarm Verification Time 40 9 Disabled Required (depends on panel & sensors)
Call Waiting Cancel Must be programmed as part of
the phone number
0 n/a n/a Required (depends on user phone line)
Default Changes (from prior
versions):
Recent Closing 23 3 / 7 Enabled
Exit Error 23 3 / 8 Enabled
Power Up Delay 40 3 60 sec.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-4 and is the answer not in the manual?

GE NetworX NX-4 Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Operating Environment IconOperating Environment
loop resistance300 Ohms Maximum
loop response500mS
operating temperature32 to 120 degrees F
Weight and Dimensions IconWeight and Dimensions
led keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
nx-148e lcd keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
metal enclosure dimension9.25" Wide, 8.25" High, 3.50" Deep