Page 13
LOCATION 3
DIAL ATTEMPTS/BACKUP CONTROL PHONE # 1
2 segments, numerical data
Segment 1 Dial attempts: Location 3, Segment 1 is used to enter the number of dial attempts (1 to 15 Attempts)
the communicator will make to Phone #1 before ending the notification process. Factory default is "8" and the
communicator will make eight (8) attempts to the first number.
Segment 2 Phone #1 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-6 to
make the designated number of attempts to Phone #1 and #2 before setting the "Fail To Communicate" condition and
stop reporting. Programming a "1" in this segment will cause the NX-6 to stop trying to communicate after the
designated number of attempts have been made to Phone #1. If a "2" is programmed in this segment, it will cause the
NX-6 to make the dial attempts in increments of two. The first two attempts will be made to Phone #1, the next two
attempts to Phone #2, then repeating until the total number of attempts designated in Segment 1 is completed.
COMMUNICATOR FORMAT SELECTIONS
DATA
FORMAT
DESCRIPTION
0
Local
Communicator is disabled
1
Universal 4+2
Two digit event code 1800hz transmit 2300hz handshake double round parity 40pps
2
3+1 fast (or 4+1)
One digit event code 1900Hz transmit 1400Hz handshake double round parity 20pps
3
Reserved
Reserved
4
Pager
3 digit event code DTMF transmission
5
3/1 or 4/1 slow
1800hz transmit 2300hz handshake double round parity 20 p.p.s. hex capability
6
3/1 or 4/1 slow
1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
7
3/1 or 4/1 fast
1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability
8
3/1 or 4/1 fast
1800hz transmit 1400hz handshake double round parity 40 p.p.s. hex capability
9
3/1 or 4/1 fast with
parity
1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex capability
10
3/1 or 4/1 fast with
parity
1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex capability
11
4+2 express
Two-digit event code DTMF transmission
12
4+2 fast
Two-digit event code 1900hz transmit 1400hz han
dshake double round parity 20
p.p.s.
13
Ademco Contact ID
DTMF (see pages 37-38)
14
SIA
FSK (see pages 37-38)
15
Custom format
(See location 18, page 16)
LOCATION 4
EVENTS REPORTED TO PHONE # 1
2 segments, feature selection
Phone #1 has two programming locations that are used to select which events are reported to this phone number.
Location 4 is used to select which events are reported to Phone #1. Location 5 is used to select which partitions are
reported to Phone #1. If dual or split reporting is not desired, location 4 should be used to select all events to Phone
#1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and the split is based on
the event type (such as alarm, open/close, etc.), location 4 should be used to select only those events that should be
reported to Phone #1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and
the split is based on partition, location 4 should be programmed as a "0" and location 5 should be used to select those
partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations should be
programmed as "0" (disabling all options). Use Table 1.1 on page 14 to identify the events to be reported for
Phone #1.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6 and is the answer not in the manual?

GE NetworX NX-6 Specifications

Operating Power IconOperating Power
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Loop Specifications IconLoop Specifications
loop resistance for standard loop300 Ohms Maximum
loop resistance for 2-wire smokes30 Ohms Maximum
loop response500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
LED Keypad Specifications IconLED Keypad Specifications
led keypad current draw130 mA max.
led keypad dimensions width6.4"
led keypad dimensions height4.0"
led keypad dimensions depth1.1"
NX-148E LCD Keypad Specifications IconNX-148E LCD Keypad Specifications
nx-148e lcd keypad current draw110 mA max.
nx-148e lcd keypad dimensions width6.4"
nx-148e lcd keypad dimensions height5.3"
nx-148e lcd keypad dimensions depth1.0"
Enclosure and Shipping IconEnclosure and Shipping
metal enclosure dimension width11.25"
metal enclosure dimension height11.25"
metal enclosure dimension depth3.50"
shipping weight9 lbs.