APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID
The NX-6 has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA consists
of an Event Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event code will come
from the chart below and be programmed in the Zone Type event code.
Programmed Event Code
SIA Code Description
0 HA Holdup Alarm
1 FA Fire Alarm
2 PA Panic Alarm
3 BA Burglary Alarm
4 BA Burglary Alarm
5 BA Burglary Alarm
6 UA Untyped Alarm
7 BA Burglary Alarm
8 BA Burglary Alarm
9 UA Untyped Alarm
10 HA Holdup Alarm
11 MA Medical Alarm
12 PA Panic alarm
13 TA Tamper Alarm
14 RP Periodic Test
15 GA Gas Alarm
16 KA Heat Alarm
17 WA Water Alarm
18 QA Emergency Alarm
19 SA Sprinkler Alarm
20 ZA Freeze Alarm
The NX-6 has the ability to report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code
and a Zone ID. The zone ID is the zone that created the alarm. The event code will come from the chart below and be
programmed in the Zone Type event code.
Programmed Event Code
Contact ID Code Description
0 122 Silent Panic
1 110 Fire Alarm
2 120 Panic Alarm
3 130 Burglary Alarm
4 131 Perimeter Alarm
5 132 Interior Alarm
6 133 24 Hour Burglary
7 134 Entry Alarm
8 135 Day/Night Alarm
9 150 Non Burglary 24 Hour
10 121 Duress Alarm
11 100 Medical Alarm
12 123 Audible Panic Alarm
13 137 Tamper Alarm
14 602 Periodic Test
15 151 Gas Detected
16 158 High Temp
17 154 Water Leakage
18 140 General Alarm
19 140 General Alarm
20 159 Low Temp

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6 and is the answer not in the manual?

GE NetworX NX-6 Specifications

Operating Power IconOperating Power
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Loop Specifications IconLoop Specifications
loop resistance for standard loop300 Ohms Maximum
loop resistance for 2-wire smokes30 Ohms Maximum
loop response500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
LED Keypad Specifications IconLED Keypad Specifications
led keypad current draw130 mA max.
led keypad dimensions width6.4"
led keypad dimensions height4.0"
led keypad dimensions depth1.1"
NX-148E LCD Keypad Specifications IconNX-148E LCD Keypad Specifications
nx-148e lcd keypad current draw110 mA max.
nx-148e lcd keypad dimensions width6.4"
nx-148e lcd keypad dimensions height5.3"
nx-148e lcd keypad dimensions depth1.0"
Enclosure and Shipping IconEnclosure and Shipping
metal enclosure dimension width11.25"
metal enclosure dimension height11.25"
metal enclosure dimension depth3.50"
shipping weight9 lbs.

Related product manuals