NX-8 Control
8
begin a new trip count where the next alarm will set the ‘counter’ to 1. If immediate restore is enabled in location 37,
the alarms (and restores, if enabled) will be sent as they occur. If immediate restore is not enabled, a second or
subsequent alarm will not be sent until the siren times out. (See location 37 and 38, page 23) Factory default is 1.
Telephone Line Monitor
- The NX-8 has a Telephone Line Monitor that monitors the voltage and current of the
telephone line for a detection of a faulted phone line. This condition can also be reported to the central station. If the
report is enabled, only the Telephone Line Restore will be reported unless the NX-870 is being used. (See locations
37, 39, and 40, pages 23-24)
Temporal Siren Disable
- If disabled, the Fire Siren will be steady and Fire Voltage Out will be the same as Burglary
(continuous). Otherwise, the Fire Siren will be temporal. (See location 37, page 23) NOTE: For UL installations,
do NOT disable.
Tone Sniff Answering Machine Defeat
- If enabled, only one call is required to defeat the answering machine. To use
this feature you must have a Hayes 1200 Smart Modem. From the computer, call the panel as normal. When the
answering machine answers, the panel will hear the tones from the modem and seize the phone line for a download.
(See location 21, page 18)
Two Call Answering Machine Defeat
- If enabled, to defeat an answering machine, two telephone calls must be
made to the premises. On the first call, let the phone ring one or two times. The control panel will detect these rings
and start a 45 second timer, during which, the control panel will answer the next call on the first ring. This is not
recommended for commercial applications. (See location 21, page 18)
Walk-Test Mode
- If enabled, entering [r] [Chime] followed by a user code will allow a walk-through zone test where
all zones become silent and local (non-reporting). During this test the chime light will flash on the LED keypad. Each
time a zone is faulted, the zone light on the LED keypad will illuminate and the chime will sound. The number of the
faulted zone(s) will be displayed on the LCD keypad. It will also be entered into alarm memory and the internal log.
To exit at any time during this mode, enter a user code. Otherwise the AWalk-Test Mode@ will automatically exit after
15 minutes. (See location 41, page 24)
Wireless Sensor Missing/Low Battery
- The NX-8 will send a report to the central station when a wireless sensor
has detected a low battery or has not reported to the receiver. The "Service" LED will illuminate when either condition
exists. (See location 37, page 23)
Zone Bypassed Sounder Alert
- If this feature is enabled, the NX-8 will beep the keypad sounder upon arming if a
zone is bypassed. (See location 23, page 19)
Zone Doubling
- This feature allows you to use the eight zones on the panel as sixteen normally closed zones. When
this feature is used European double E.O.L. configuration cannot be used on the first sixteen zones. THIS FEATURE
DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 48. If one of the sixteen zones
must be a fire zone, it must be one of Zones 1 to 8. The corresponding upper zone will become unavailable. For
example, if Zone 6 is a fire zone, then Zone 14 will not be available. (See location 37, page 23)
Zone Types (Configurations)
- The NX-8 has 20 programmable Zone Types that determine how each zone will
function and report. The default Zone Types are listed on page 20. (See locations 111-149, pages 35-38)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-1308E - Caddx 8 Zone LED Keypad and is the answer not in the manual?

GE NX-1308E - Caddx 8 Zone LED Keypad Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E power supply12 VDC Regulated 2 AMPS
LED keypad current draw130 mA max.
LED keypad zones normal w/o sounder55 mA
NX-148E LCD keypad current draw110 mA max.
NX-148E LCD keypad w/o sounder75 mA
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Weight and Dimensions IconWeight and Dimensions
LED keypad width6.4"
LED keypad height4.0"
LED keypad depth1.1"
NX-148E LCD keypad width6.4"
NX-148E LCD keypad height5.3"
NX-148E LCD keypad depth1.0"
metal enclosure width11.25"
metal enclosure height11.25"
metal enclosure depth3.50"
shipping weight9 lbs.