GE Security
g
APPENDIX A – EVENT LOG
NOTE: Your system may not have all of the features listed in this table.
DISPLAY DESCRIPTION
TXlobat Transmitter Low Battery The transmitter has a low battery.
ZN Lost Zone Lost A wireless or multiplexed zone device is not reporting to
the control.
Duress Duress The control has been armed or disarmed with a Duress
code.
Man Fire Manual Fire Keypad “Fire” has been activated.
Aux 2 Auxiliary 2 Keypad “Medical” has been activated.
Panic Panic Keypad “Panic” has been activated.
KP Tamper Keypad Tamper The keypad tamper has been activated.
BoxTamp Box Tamper The box tamper circuit has been activated.
AC Fail AC Fail AC failure has been detected.
OverCur Over Current A short circuit of a power supply has occurred.
Srn Tamp Siren Tamper A siren or speaker tamper has been detected.
Tel Flt Telephone Fault A telephone fault or tamper has been detected.
Exp Trb Expansion Trouble An expansion device or keypad is not reporting to the
control.
Log Full Log Full The event log is full. Old events will be pushed out as new
ones enter the log.
Open Open Reports user number, date, time and partition of opening.
Close Close Reports user number, date, time and partition of closing.
Exit Err Exit Error Entry/Exit zone was faulted at the instant the exit delay
expired.
Rec Close Recent Close An alarm occurred within 5 minutes after the control was
armed.
Autotest Auto Test Sending a communicator test at a specified interval.
Start Prog Start Programming Local programming is started.
End Prog End Programming Local programming is ended.
Start Dnld Start Download Download session is started.
End Dnld End Download Download session is ended.
Cancel Cancel System is disarmed and the Cancel button was pressed
within 5 minutes of an alarm.
Gnd Flt Ground Fault A short to ground has been detected.
Man Test Manual Test Bell and/or communicator test while system is in disarmed
condition.
Re-exit Re-Exit The exit delay has been re-started without disarming the
system.
Output Trip Output Trip A trip has occurred on an expander auxiliary output.
Data Lost Data Lost Communication of a signal has failed (log only event).
Walk-test Walk-Test A zone “Walk-Test” mode has been activated.
End Test End Test Test has been ended.
Cross-Trip Cross Trip The first zone of a cross zone has been tripped (log only).
Expansion
Event
Expansion Event An expansion module created an undefined event.
Partial Arm Partial Arm Reports a closing in the stay mode.
Listen In Listen In A listen in function has been activated.
Service Start Service Start Technician is on site.
Service End Service End Technician is off site.
Code Entry Code Entry A code has been entered.
NX-148E User manual Page 26 04/10/04