31
Subject to technical modications
10.6. Measuring the tie bar bending (tie bar crack detection)
The software can display each sensor separately and thus measure the bending per tie bar
simultaneously and without additional device.
If the inner bending is less than the outer one by factors (e.g.: 80 to 400µε), this is an indication that the
tie bar (the column) is cracked on the inside and no longer carries locally.