Important Two-Component Material Information
312066ZAD 9
For all applications except spray
foam
Material Self-ignition
Keep Components A and B
Separate
Moisture Sensitivity of
Isocyanates
Exposure to moisture (such as humidity) will cause ISO to par-
tially cure, forming small, hard, abrasive crystal that become
suspended in the fluid. Eventually a film will form on the sur-
face and the ISO will begin to gel, increasing in viscosity.
NOTE: The amount of film formation and rate of crystallization
varies depending on the blend of ISO, the humidity, and the
temperature.
Spraying or dispensing fluids that contain isocyanates cre-
ates potentially harmful mists, vapors, and atomized partic-
ulates.
Read and understand the fluid manufacturer’s warn-
ings and Safety Data Sheet (SDS) to know specific
hazards and precautions related to isocyanates.
Use of isocyanates involves potentially hazardous pro-
cedures. Do not spray with this equipment unless you
are trained, qualified, and have read and understood
the information in this manual and in the fluid manufac-
turer’s application instructions and SDS.
Use of incorrectly maintained or mis-adjusted equip-
ment may result in improperly cured material. Equip-
ment must be carefully maintained and adjusted
according to instructions in the manual.
To prevent inhalation of isocyanate mists, vapors, and
atomized particulates, everyone in the work area must
wear appropriate respiratory protection. Always wear a
properly fitting respirator, which may include a sup-
plied-air respirator. Ventilate the work area according
to instructions in the fluid manufacturer’s SDS.
Avoid all skin contact with isocyanates. Everyone in the
work area must wear chemically impermeable gloves,
protective clothing and foot coverings as recom-
mended by the fluid manufacturer and local regulatory
authority. Follow all fluid manufacturer recommenda-
tions, including those regarding handling of contami-
nated clothing. After spraying, wash hands and face
before eating or drinking.
Some materials may become self-igniting if applied too
thick. Read material manufacturer’s warnings and Safety
Data Sheet (SDS).
Cross-contamination can result in cured material in fluid
lines which could cause serious injury or damage equip-
ment. To prevent cross-contamination:
Never interchange component A and component B
wetted parts.
Never use solvent on one side if it has been contami-
nated from the other side.
NOTICE
Partially cured ISO will reduce performance and the life of all
wetted parts.
Always use a sealed container with a desiccant dryer in
the vent, or a nitrogen atmosphere. Never store ISO in
an open container.
Keep the ISO pump wet cup or reservoir (if installed)
filled with appropriate lubricant. The lubricant creates a
barrier between the ISO and the atmosphere.
Use only moisture-proof hoses compatible with ISO.
Never use reclaimed solvents, which may contain mois-
ture. Always keep solvent containers closed when not in
use.
Always lubricate threaded parts with an appropriate
lubricant when reassembling.

Table of Contents

Other manuals for Graco Reactor E-20 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor E-20 Series and is the answer not in the manual?

Graco Reactor E-20 Series Specifications

General IconGeneral
BrandGraco
ModelReactor E-20 Series
CategoryPaint Sprayer
LanguageEnglish

Related product manuals