DC Inverter Multi VRF System
6
Fig.2
3.3 Piping Work Requirements
Refer to the table below for piping work requirements:
R410A Refrigerant System
Outer diameter (mm/inch)
Wall thickness(mm)
Φ6.35(1/4)
0.8
Φ9.52(3/8)
0.8
Φ12.70(1/2)
0.8
Φ15.9(5/8)
1.0
Φ19.05(3/4)
1.0
Φ22.20(7/8)
1.2
Φ25.40(8/8)
1.2