EasyManuals Logo
Home>Harman>Stove>P43

Harman P43 Installation Manual

Harman P43
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/1410 3-90-436168i
Figure 3.3
P43-Minimumsizerectangularoorprotection(USA)is32
1/2
"wideBy33"deep(825mmX838mm).
P61A-Minimumsizerectangularoorprotection(USA)is28
5/16
”DeepBy24
3/4
”Wide(719mmX629mm).
P68-Minimumsizerectangularoorprotection(USA)is33”DeepBy25”Wide(838mmX635mm).
*FloorprotectiondimensionsforthefrontandsidesaremeasuredfromtheappliancedooropeninginTheUnitedStates.In
Canada,thesidedimensionismeasuredfromthewidestpartoftheappliance.
NOTE:Measurement"L"ismeasuredfrom
thepedestalbaseintheUSONLY
NOTE:Measurement“K”ismeasuredfrom
theglassintheUSONLY
L
J
Floor Protection
Requirements
US
Canada
Sides
Rear
6" 200mm
6" 200mm
K
Front
6" 450mm
J
USA
K
L
J
CANADA
Floor protector
C. Floor Protection
Place the stove on a noncombustible type oor or oor
protectorthatextendsaminimumof6inches(152mm)tothe
frontoftheloaddooropening,6inches(152mm)tothesides
ofthedooropening,and6inchestotherear.Floorprotection
mustalsoextend2inches(51mm)beyondeachsideofany
horizontal ue pipe. The minimum oor protector material
is20gaugesheetmetal.Otheroorprotectormaterialsare
ceramictile,stone,brick,etc.Figure3.3
NOTE for Canadian installation only:PerULC-S627-00,
If installed on a combustible oor, the need to provide a
noncombustible oor protector covering the area beneath
thespaceheaterandextendingatleast17.72”(450mm)on
theringsideandatleast7.87”(200mm)ontheothersides.
In Canada, you may follow smaller U.S. oor protection
requirements ONLY if the user agrees to completely
shut-down the appliance, and allow it to cool to where
all re is extinguished and the combustion blower and
its indicator light shuts off, prior to opening the rebox
door or ash door.
D. Mobile Home Installation
When installing this unit in a mobile home, several
requirementsmustbefollowed:
1. Theunitmustbeboltedtotheoor.Thiscanbedonewith
1/4”lagscrewsthroughthe2holesinthebaseplate.
2. Theunitmustalsobeconnectedtooutsideair.Seesection
4-DOutsideAir.
3. Floor protection and clearances must be followed as
shown.
4. Unitmustbegroundedtothemetalframeofthemobile
home.
P43 = 42-5/8”
P61A/P68 = 50”
Corner to edge dimension for corner installation oor protection.

Other manuals for Harman P43

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P43 and is the answer not in the manual?

Harman P43 Specifications

General IconGeneral
BrandHarman
ModelP43
CategoryStove
LanguageEnglish

Related product manuals