Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/1410 3-90-436168i
Figure 3.3
P43-Minimumsizerectangularoorprotection(USA)is32
1/2
"wideBy33"deep(825mmX838mm).
P61A-Minimumsizerectangularoorprotection(USA)is28
5/16
”DeepBy24
3/4
”Wide(719mmX629mm).
P68-Minimumsizerectangularoorprotection(USA)is33”DeepBy25”Wide(838mmX635mm).
*FloorprotectiondimensionsforthefrontandsidesaremeasuredfromtheappliancedooropeninginTheUnitedStates.In
Canada,thesidedimensionismeasuredfromthewidestpartoftheappliance.
NOTE:Measurement"L"ismeasuredfrom
thepedestalbaseintheUSONLY
NOTE:Measurement“K”ismeasuredfrom
theglassintheUSONLY
L
J
Floor Protection
Requirements
US
Canada
Sides
Rear
6" 200mm
6" 200mm
K
Front
6" 450mm
J
USA
K
L
J
CANADA
Floor protector
C. Floor Protection
Place the stove on a noncombustible type oor or oor
protectorthatextendsaminimumof6inches(152mm)tothe
frontoftheloaddooropening,6inches(152mm)tothesides
ofthedooropening,and6inchestotherear.Floorprotection
mustalsoextend2inches(51mm)beyondeachsideofany
horizontal ue pipe. The minimum oor protector material
is20gaugesheetmetal.Otheroorprotectormaterialsare
ceramictile,stone,brick,etc.Figure3.3
NOTE for Canadian installation only:PerULC-S627-00,
If installed on a combustible oor, the need to provide a
noncombustible oor protector covering the area beneath
thespaceheaterandextendingatleast17.72”(450mm)on
theringsideandatleast7.87”(200mm)ontheothersides.
In Canada, you may follow smaller U.S. oor protection
requirements ONLY if the user agrees to completely
shut-down the appliance, and allow it to cool to where
all re is extinguished and the combustion blower and
its indicator light shuts off, prior to opening the rebox
door or ash door.
D. Mobile Home Installation
When installing this unit in a mobile home, several
requirementsmustbefollowed:
1. Theunitmustbeboltedtotheoor.Thiscanbedonewith
1/4”lagscrewsthroughthe2holesinthebaseplate.
2. Theunitmustalsobeconnectedtooutsideair.Seesection
4-DOutsideAir.
3. Floor protection and clearances must be followed as
shown.
4. Unitmustbegroundedtothemetalframeofthemobile
home.
P43 = 42-5/8”
P61A/P68 = 50”
Corner to edge dimension for corner installation oor protection.