Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/149 3-90-436168i
Duetohightemperatures,thestoveshouldbeplacedoutof
trafcandawayfromfurnitureanddraperies.
Childrenandadultsshouldbealertedtothehazardsofhigh
surfacetemperaturesandshouldstayawaytoavoidburns
toskinand/orclothing.
Youngchildrenshouldbecarefullysupervisedwhentheyare
inthesameroomasthestove.
Clothingandotherammablematerialsshouldnotbeplaced
onornearthisunit.
Alternate oor protector dimension may be used as long as they satisfy the measurement requirements shown below.
Minimum size oor protection for a corner installation hearth pad is 36" x 36".
B. Clearances to Combustibles
Whenselectingalocationfortheapplianceitisimportantto
considertherequiredclearancestowalls(seeFigure3.2).
Figure 3.2
CAUTION
THIS APPLIANCE MUST BE VENTED TO THE OUTSIDE.
WARNING
RISK OF FIRE OR BURNS! Provide adequate
clearance around air openings and for service
access. Duetohightemperatures,theapplianceshould
be located out of trafc and away from furniture and
draperies.
NOTICE: IllustrationsreecttypicalinstallationsandareFOR
DESIGNPURPOSESONLY.Actualinstallationmayvarydue
toindividualdesignpreference.
Placethestoveawayfromcombustiblewallsatleastasfar
asshowninFigure3.2.Pleasenotethedifferenceinside
wallclearancewithandwithoutsideshields.
Notethattheclearancesshownareminimumforsafetybutdo
notleavemuchroomforaccesswhencleaningorservicing.
Pleasetakethisintoaccountwhenplacingthestove.
9"(228mm)WithSideShields
13"(330mm)WithoutSideShields
9"(228mm)-
13"(330mm)
9"(228mm)-
13"(330mm)
9"(228mm)WithorWithoutSideShields
9"(228mm)
9"(228mm)
*10"(254mm)with
sideshields
*16"(406mm)
withoutsideshields
2"(51mm)
36"(914mm)
*10"(254mm)
*16"(406mm)
2"(51mm)
36"(914mm)
14"(355mm)
20"(508mm)
14"(355mm)with
sideshields
20"(508mm)
withoutsideshields
P43 Freestanding Pellet StoveP61A & P68 Freestanding Pellet Stove