16PC 45 Corn/Pellet Stove
3-90-02686R29_05/14
H
L
L
H
6
2
7
1
3
4
5
75°
90°
85°
80°
70°
65°
60°
55°
50°
OFF
R
O
O
M
T
E
M
P
S
T
O
V
E
T
E
M
P
6
4
5
2
3
1
H
L
L
H
MAX.
CORN
TEST
POWER
STATUS
DISTRIBUTION
COMBUSTION
BLOWER
BLOWER
FEED MOTOR
IGNITER
6
2
7
1
3
4
5
75°
90°
85°
80°
70°
65°
60°
55°
50°
OFF
R
O
O
M
T
E
M
P
S
T
O
V
E
T
E
M
P
AUTO
MANUAL
IGNITER
F
E
E
D
A
D
J
U
S
T
E
R
P
E
L
L
E
T
O
N
L
Y
C
O
R
N
-
P
E
L
L
E
T
ThePC45Corn/PelletStoveiscapableofmanualoperation.Thisalsoallowstheoperatortomanually
controloperationduringanemergency(i.e.igniterfailure,whenusingsometypesofauxiliarypower.)
Theunitcanbeswitchedbetween"AUTO"and"MANUAL"atanytimeduringoperation.
NOTE: When starting the unit in the "AUTO" mode and switching to "MANUAL", wait until the
igniter light (located on the control board) comes on to conrm the ignition cycle has begun.
Manual Operation
Fig.22:RoomTemperatureMode:Thissettingwillproducea
roomtemperatureof70degreeswiththedistributionblowerat
mediumspeed.
Fig.23:Thissettingwillproducealargeviewingrewithouta
distributionbloweroperating.
6
4
5
2
3
1
H
L
L
H
( WARNING ) HIGH VOLTAGE
Disconnect power before opening cover.
MAX.
CORN
TEST
POWER
STATUS
DISTRIBUTION
COMBUSTION
BLOWER
BLOWER
FEED MOTOR
IGNITER
6
2
7
1
3
4
5
75°
90°
85°
80°
70°
65°
60°
55°
50°
OFF
R
O
O
M
T
E
M
P
S
T
O
V
E
T
E
M
P
AUTO
MANUAL
IGNITER
F
E
E
D
A
D
J
U
S
T
E
R
P
E
L
L
E
T
O
N
L
Y
C
O
R
N
-
P
E
L
L
E
T
Manual Stove Temperature Mode
Igniter Switch to "MANUAL" / Room Temp Mode
Therewillhavetobelitwithstartinggelandamatch,or
started automatically, see "Automatic Operation". Turn to
"Manual"positionwhentheignitioncyclehasstarted.
Thedifferencebetween"AUTO"RoomTemperatureMode
and"Manual"RoomTemperatureModeisthattherewillnot
gooutastheroomtemperaturegoesabovethecontrolboard
setting.Theunitcanonlygotolowburnandwillremainthere
untilitrunsoutoffueloruntilmoreheatisneededandthe
feedrateincreases.Feedrateadjustmentsanddialsettings
arethesameas"AUTO"settings.
Igniter Switch to "MANUAL" / Stove Temp Mode
Theadvantageofthismodeistoallowtheoperatortohave
alargeviewingrewithoutblowingextraheatintotheroom.
Duringoperation,withthetemperaturedialsetat#4orless,
thedistributionfanwillnotoperate.Therefore,therecanbe
ahigherburnrate(alargerviewingre)withoutanexcess
ofhotairblowingintotheroom.
AnexampleofwhentousetheManualStoveTemperature
Modeisif you wanttowatcha large reandtheroom is
already up to temperature. The StoveTemperature Mode
allows you to have a larger re and a lower sound level,
withoutthedistributionblower.
NOTE: During the use of this mode, if you keep increasing
the temperature dial setting to increase the re size, the
distribution blower will automatically come on when the
ESP Temperature reaches 350
°
F, or 81% output.