16PC 45 Corn/Pellet Stove
3-90-02686R29_05/14
H
L
L
H
6
2
7
1
3
4
5
75°
90°
85°
80°
65°
60°
55°
50°
OFF
R
O
O
M
T
E
M
S
T
O
V
E
T
E
M
P
6
4
5
2
3
1
H
L
L
H
( WARNING ) HIGH VOLTAGE
Disconnect power before opening cover.
MAX.
CORN
TEST
POWER
STATUS
DISTRIBUTION
COMBUSTION
BLOWER
BLOWER
FEED MOTOR
IGNITER
6
2
7
1
3
4
5
75°
90°
85°
80°
70°
65°
60°
55°
50°
OFF
R
O
O
M
T
E
M
P
S
T
O
V
E
T
E
M
P
AUTO
MANUAL
IGNITER
F
E
E
D
A
D
J
U
S
T
E
R
P
E
L
L
E
T
O
N
L
Y
C
O
R
N
-
P
E
L
L
E
T
ThePC45Corn/PelletStoveiscapableofmanualoperation.Thisalsoallowstheoperatortomanually
controloperationduringanemergency(i.e.igniterfailure,whenusingsometypesofauxiliarypower.)
Theunitcanbeswitchedbetween"AUTO"and"MANUAL"atanytimeduringoperation.
NOTE: When starting the unit in the "AUTO" mode and switching to "MANUAL", wait until the
igniter light (located on the control board) comes on to conrm the ignition cycle has begun.
Manual Operation
Fig.22:RoomTemperatureMode:Thissettingwillproducea
roomtemperatureof70degreeswiththedistributionblowerat
mediumspeed.
Fig.23:Thissettingwillproducealargeviewingrewithouta
distributionbloweroperating.
6
4
5
2
3
1
H
L
L
H
( WARNING ) HIGH VOLTAGE
Disconnect power before opening cover.
MAX.
CORN
TEST
POWER
STATUS
DISTRIBUTION
COMBUSTION
BLOWER
BLOWER
FEED MOTOR
IGNITER
6
2
7
1
3
4
5
75°
90°
85°
80°
70°
65°
60°
55°
50°
OFF
R
O
O
M
T
E
M
P
S
T
O
V
E
T
E
M
P
AUTO
MANUAL
IGNITER
F
E
E
D
A
D
J
U
S
T
E
R
P
E
L
L
E
T
O
N
L
Y
C
O
R
N
-
P
E
L
L
E
T
Manual Stove Temperature Mode
Igniter Switch to "MANUAL" / Room Temp Mode
Therewillhavetobelitwithstartinggelandamatch,or
started automatically, see "Automatic Operation". Turn to
"Manual"positionwhentheignitioncyclehasstarted.
Thedifferencebetween"AUTO"RoomTemperatureMode
and"Manual"RoomTemperatureModeisthattherewillnot
gooutastheroomtemperaturegoesabovethecontrolboard
setting.Theunitcanonlygotolowburnandwillremainthere
untilitrunsoutoffueloruntilmoreheatisneededandthe
feedrateincreases.Feedrateadjustmentsanddialsettings
arethesameas"AUTO"settings.
Igniter Switch to "MANUAL" / Stove Temp Mode
Theadvantageofthismodeistoallowtheoperatortohave
alargeviewingrewithoutblowingextraheatintotheroom.
Duringoperation,withthetemperaturedialsetat#4orless,
thedistributionfanwillnotoperate.Therefore,therecanbe
ahigherburnrate(alargerviewingre)withoutanexcess
ofhotairblowingintotheroom.
AnexampleofwhentousetheManualStoveTemperature
Modeisif you wanttowatcha large reandtheroom is
already up to temperature. The StoveTemperature Mode
allows you to have a larger re and a lower sound level,
withoutthedistributionblower.
NOTE: During the use of this mode, if you keep increasing
the temperature dial setting to increase the re size, the
distribution blower will automatically come on when the
ESP Temperature reaches 350
°
F, or 81% output.