Harman® • PF-120 Owner’s Manual_R3 • 2014 -___ • 10/1410
3-90-08120c
I. Low Fuel Sensor
Thereisalowfuelsensorinthehopperthattellsthecontrol
that the fuel level in the hopper has dropped below the
sensor.Whenthishappens,theLowFuellightontheWall
Controlwillstarttoblink.Youthenknowthatitistimetoll
thehopperwithpellets.
Note:Testing the low fuel sensorcanbedoneby turning
theFEEDADJUSTERknobto“Test”.ThePOWERlightwill
gooffwhenthesensorisuncoveredandwilllightwhenthe
sensoriscoveredagain.
Note: TheLOWFUELlightontheFurnaceControlwilllight
atthesametime.OnlytheLOWFUELlightontheFurnace
Controlwillremainlitforthreeminutesafterthesensoris
coveredwithpellets.SeeNotebelow.
Note: TheLowFuellightindicatesthatthereispowergoing
totheauxiliaryleadsinthecircuitbreakerjunctionbox.(120
VAC60HzMax.1Amp.)Theauxiliarypowerleadscouldbe
usedifabulkhopperandaugersystemwereinstalled.(see
wiringdiagramonpage36)
Type of Fuel
Pelletizedwoodonly.
Note:Thelowertheashcontentofthepelletsmeansless
heatexchangersurfacecleaningthatwillbeneeded.The
cleaner thesesurfaces are kept, the moreefcient the
furnacewillbe.
DO NOT BURN GARBAGE, GASOLINE, NAPTHA,
ENGINE OIL OR OTHER INAPPROPRIATE MATERIALS
CAUTION
!
G. Before Your First Fire
1. Makesureyourappliancehasbeenproperlyinstalledand
thatallsafetyrequirementshavebeenmet.Payparticular
attentiontothereprotectionandventinginstructions.
2. Doublecheckthattheashpanandreboxareempty!
3. Closethefrontdoor.
H. Wall Control
Thewallcontrolactslikeathermostat,athermisterinthe
wallcontrolissendingtemperatureinformationbacktothe
microprocessoronthefurnace.Thisinformationisusedto
determinetheneedtoincreaseordecreasethesizeofthe
reaccordingtothetemperaturedemand.
Setting The Room Temperature
To settheroom temperature, simplyturnthe temperature
dialtothedesiredsetting.Thecontrolandthefurnacewill
thenperformtoachievethesettemperature.
Note: The minimum temperature you can set with a full
counter-clockwiseknobpositionis58degrees.Themaximum
temperatureyoucansetwithafullclockwiseknobposition
is90degrees.
WallControlcalibration:The“NormalSetting”ontheTemp
DialoftheFurnaceControl(SeeFig.44)calibratestheWall
Controltemperaturespan.IftheTempDialisnotpointingto
the“NormalSetting”,thetemperaturespancouldvaryby3
degreesupordowndependingontheTempDialknobsetting.